62 
Ambient 
temperature 
setting 
Set range is, 
-10 to 50 C 
Two option codes: 
OFF 
ON (press STR then clear) 
Set range is, 
1. to 1000. 
Sets the starting frequency for the inverter 
output, range is 0.10 to 9.99 Hz 
Sets the PWM carrier (internal switching 
frequency), range is 2.0 to 10.0 kHz 
Initialization mode 
(parameters or trip 
history) 
Select initialized data, five option codes: 
Initialization disabled 
Clears Trip history 
Initializes all Parameters 
Clears Trip history and initializes all 
parameters 
Clears Trip history and initializes all 
parameters and EzSQ program 
Country for 
initialization 
Mode 1, Mode 0, Mode 3 
Frequency scaling 
conversion factor 
Specify a constant to scale the displayed 
frequency for  monitor, range is 0.01 to 
99.99 
Select whether the STOP key on the keypad is 
enabled, three option codes: 
Enabled 
Disabled always 
 Disabled for stop 
Selects how the inverter resumes operation 
when free-run stop (FRS) is cancelled, three 
options: 
Restart from 0Hz 
Restart from frequency detected from real 
speed of motor (freq. matching) 
Restart from frequency detected from real 
speed of motor (active freq. matching) 
Automatic carrier 
frequency 
reduction 
Three option codes: 
Disabled 
Enabled, depending on the output current 
Enabled, depending on the heat-sink 
temperature 
Dynamic braking 
usage ratio 
Selects the rate of use (in %) of the 
regenerative braking resistor per 100 sec. 
intervals, range is 0.0 to the value calculated 
by the value of b097. 
If the connected resister’s allowable range is 
narrower then above range, the resister’s 
range is prior. 
0%: Function disabled 
>0%: Enabled, per value 
Select how the inverter stops the motor, two 
option codes: 
DEC (decelerate to stop) 
FRS (free-run to stop)