29
PMML0291A rev.2 - 09/2014
INSTALLATION
ENGLISH
Connection procedure
Perform the exible water pipes connection between indoor unit 
and domestic hot water tank (Indoor unit water connections) as
follows:
1 Remove the indoor unit covers protection to facilitate the con-
nection procedure.
2 Remove the metal plugs (Heating coil connections) from the
3-way valve and the T-branch. If necessary, disconnect the
3-way valve motor (upper part) to ease the installation pro-
cedure.
3-way valve con-
nection for heating
coil inlet
Metal plug
3-way valve
motor
(upper part)
3-way valve T-branch
Metal
plug
T-branch connec-
tion for heating
coil outlet
3-way valve connection for
heating coil inlet
(Left side view)
T-branch connection for
heating coil outlet
3 Before performing the water pipe connections, bend the pipes
approximately as in the following gures. By this way, the pipe 
end which will be connected to the tank’s heating coil, will be
placed closer to its nal connection position.
Recommended position of the heating coil inlet
pipe (short pipe 365 mm tube length)
(Front view)
3-way valve con-
nection for heating
coil inlet
Recommended position of the heating coil outlet
pipe (long pipe 960 mm tube length)
(Front view)
(Top view)
T-branch con-
nection for
heating coil
outlet
R>90mm
R ≥ 90mm

Table of Contents