EasyManua.ls Logo

Hiwin MG Series - Page 61

Hiwin MG Series
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
61
Assembly instructions
Linear Guideways
GW-04-0-EN-1910-MA
12.3.3 Height tolerance for mounting areas on block (S
2
/S
3
)
The height tolerance of the reference surface in the parallel use of two or more blocks (S2/S3)
S
2
=
b × K
S
2
Max. height tolerance [mm]
b Distance between two blocks [mm]
K Coefficient of the height tolerance
S
3
Max. height tolerance [mm]
b Distance between two blocks [mm]
K Coefficient of the height tolerance
S
3
=c × K
Series Size Load type
CG_C CG_H
CG 15 – 45 4.2 × 10
–5
3.0 × 10
–5
Series Size Load type
RG_C/QR_C RG_H/QR_H
RG 15 – 65 4.2 × 10
–5
3.0 × 10
–5
QR 25 – 45 4.2 × 10
–5
3.0 × 10
–5
Table 12.6 Coefficient of the height tolerance (K) – CG series
Fig. 12.3 Max. height tolerance S
2
Fig. 12.4 Max. height tolerance S
3
b
0.010
0.010
0.010
0.010
0.010
S
2
B
B
A
A
A
A
Accuracy requirement for
all block-mounting reference surfaces
c
0.010
0.010
A
S
3
Accuracy requirement for
all block-mounting reference surfaces
Table 12.7 Coefficient of the height tolerance (K)

Related product manuals