EasyManua.ls Logo

Hobart Handler 135 - Process and Polarity Setup

Hobart Handler 135
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OM-944 Page 13
3-3. Process/Polarity Table
Cable Connections
Process Polarity
Cable To Gun Cable To Work
GMAW Solid wire with shield-
ing gas
DCEP Reverse polarity Connect to positive (+) out-
put terminal
Connect to negative () output
terminal
FCAW Self-shielding wire
no shielding gas
DCEN Straight Polarity Connect to negative ()
output terminal
Connect to positive (+) output
terminal
3-4. Changing Polarity
1 Lead Connections For Direct
Current Electrode Positive
(DCEP)
2 Lead Connections For Direct
Current Electrode Negative
(DCEN)
Always read and follow wire
manufacturers recommended po-
larity, and see Section 3-3.
Close door.
1
Ref. 196 052
2

Table of Contents