Configuring Event Settings
53
12.
Click Save to apply the settings.
Configuring People Counting Events
Note Only for H4L6GR2 and HBL6GR2.
People Counting
You can track the movement of people entering or leaving an area using the people counter
function.
1.
Select the Enable check box to enable the people counting function.
2.
Click Draw Rule and then drag your mouse over the area of the video image that you
want to monitor.
3.
Click Draw Target, and then, next to Target Filter, select Max Size. Use your mouse to
draw the maximum target size. Next, select Min Size, and use your mouse to draw the
minimum target size.
4.
Click Setup to to set the days and times when you want the people counting function to
be active.
5.
Enter a name for the rule.
6.
Select the flow direction: A->B or B->A.
7.
Enter the desired values for Enter Number, Leave Number, and Stranded Number.
When any of the numbers is exceeded, an alarm is generated.
8.
Select the check box to start recording video when an alarm is generated.
9.
Enter the time that the system will continue recording video after an alarm is generated
(10300 seconds).
10.
Select the Alarm Output check box to activate an alarm output when an alarm is
generated.
11.
Enter the time that the system will continue to generate an alarm output after an alarm

Table of Contents