HCE80(R) / HCC80(R) Mounting and operation
5
The underfloor heating controller
offers the following functions:
5 controllable temperature zones, extendable to 8
Up to 3 thermal actuators can be connected per zone
Normally open or normally closed
thermal actuators can be used
Integrated pump relay
Boiler feedback
Analog (only HCE80/HCC80)
Integrated relay with floating contact
42VAC/VDC (only at HCE80R, HCC80R)
Wireless via relay BDR91
Underfloor heating controller can be
switched between heating and cooling
1 antenna (internal or external) can
be used for 3 controllers
Rapid installation through screwless
terminals of the thermal actuators
Intelligent controlling via fuzzy logic
Simple diagnoses of the wireless transmission
Operating state display via LEDs
HCE80 HCE80R HCC80 HCC80R
Antenna
External External Internal Internal
Pump relay
230 VAC internal 230 VAC internal 230 VAC internal 230 VAC internal
Analog output
Available Not available Available Not available
Boiler feedback radio
External with BDR91 External with BDR91 External with BDR91 External with BDR91
Boiler feedback relay
Not available 42 VAC/VDC Not available 42 VAC/VDC
The pump relay 230VAC is not oating.
!
Function overview

Table of Contents

Other manuals for Honeywell HCE80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell HCE80 and is the answer not in the manual?

Honeywell HCE80 Specifications

General IconGeneral
BrandHoneywell
ModelHCE80
CategoryController
LanguageEnglish

Related product manuals