76 | equIP® Series 30x Zoom WDR PTZ Camera User Guide
Note Before setting up auto tracking, you must first save a preset and then add a smart
plan to the preset.
To set up auto tracking:
1. Select a preset for auto tracking from the Preset list.
2. In the Parameter area, set Anti-Disturb Enable to ON or OFF. When enabled,
anti-disturb reduces false alarms from movement in the scene (such as leaves moving
in the wind).
3. Set Shadow Scene Enable to ON or OFF. When enabled, shadow scene reduces false
alarms from shadows in the scene.
4. Move the Sensitivity slider to set the desired detection sensitivity.
5. In the Advanced Parameter area, set the Tracking Overlap Rate, Valid Tracking
Distance, and Valid Tracking Time.
6. Click Save to apply the settings.
Configuring Face Detection Events
You can configure face detection event settings on the Setup > IVS Analysis > Face
Detection page.
Tracking Overlap Rate Calculates the overlap between an object’s current position and its
starting position. The higher the setting, the more sensitive the
tracking detection will be.
Valid Tracking Distance Auto tracking only detects objects within the Valid Tracking
Distance. The lower the setting, the more sensitive the tracking
detection will be.
Valid Tracking Time Auto tracking stops when the Valid Tracking Time elapses (1 = 0.1
seconds; 20 = 2 seconds).