INTELLIGUARD 9000™
74-3047—18
MOUNT THE HEDS IV
See Fi
. 7 for a t
pical door-mounted HEDS IV.
1.
Remove the HEDS IV ma
net assembl
cover and the
two ma
nets b
loosenin
the two set screws
re
uires
hex allen ke
. This allows access to the mountin
holes
located under the ma
nets.
2.
Mount the ma
net assembl
on the door at the selected
mountin
location
as far awa
from the hin
e side as
possible
usin
two No. 6 round or pan head screws.
3.
Reinstall the two ma
nets
red markin
s on ma
nets
must be facin
toward the support closest to the ed
e of
the plastic base and flush with the support
and ti
hten
the two set screws.
Fig. 7. HEDS IV typical door mount position.
4.
Reinstall the cover.
5.
Remove the
L
shaped cover of the HEDS IV unit
assembl
. See Fi
. 8.
6.
Select one of the cable entr
options shown in Fi
. 8
and drill or bend the cable entries.
7.
Ali
n the HEDS IV unit assembl
with the HEDS IV
ma
net assembl
and mount usin
two flat head
screws. The spacin
between both units must not
exceed 3/16 in.
4.76 mm
. Do not allow the two parts to
touch when the door is closed.
8.
Feed the cable
s
into the unit.
9.
Connect the wires to the terminals as indicated in Fi
. 6.
10.
Do not install the
L
shaped cover until the device is cali-
brated and learned.
11.
Learn the HEDS IV usin
step 11a. or 11b.
a. With the protected door open, start the LEARNING
Mode
DEVICES WITH SERIAL #
at a CC2. Press
and hold the HEDS IV learn push button
S1
for one
second. This also starts the calibration process. At
the CC2, end the learnin
procedure and proceed to
step 12b.
b. Take note of the HEDS IV serial number, enter it
athered information from all devices, enter and
download once to save time
into PRO 9000 and
download it into the I9000.
12.
Calibrate the HEDS IV.
a. With the protected door open, press and hold
S1
for
one second.
b. Replace the HEDS IV cover.
c. Close the door.
d. Send the
Reset Detector
command from the CC2.
13.
Repeat steps 1 throu
h 12 for each HEDS IV.
14.
From the CC2, exit the CONFIGURATION Menu for
chan
es to become effective.
Fig. 8. Cable entry options.
6-Input/Output Concentrators (BIC-6)
Most detection devices connect to a 6-Input Concentrator
BIC-6
. Each BIC-6 accepts a maximum of six inputs and
rela
s the si
nal to the CU as a sin
le output to reduce the
amount of direct wirin
to the CU. Each CU supports a
maximum of 31 BIC-6s on each COM, for a total of 62. These
totals include all device t
pes shown in Fi
. 2. Fi
. 9 shows
wirin
terminals and pro
rammin
buttons on a BIC-6.
.To install the BIC-6:
1.
Remove the BIC-6 cover at the selected mountin
loca-
tion.
2.
Use a no. 1 Robertson
s
uare drive
screwdriver to
remove the screws securin
the circuit board to the
back casin
.
IMPORTANT
Touch a grounded object to ensure you are not elec-
trostatically charged before handling the circuit
board.
HEDS IV
TOP
HEDS IV
BOTTOM
(CONTAINS
MAGNET)
DOOR
M16108
KNOCKOUT
HEDS IV COMPLETE
ASSEMBLY 8003-283
(INCLUDES SENSOR
AND MAGNET ASSEMBLY)
SENSOR 8003-280
MAGNET ASSEMBLY
8003-282
DRILL ONE OR TWO HOLES AS
REQUIRED ANYWHERE ON THIS
SURFACE. VERIFY FOR OBSTACLES
ON OPPOSITE SIDE FIRST.
M14547
COVER
(NON-REMOVABLE)
8003-280 UNIT ASSEMBLY
(ENCLOSURE ONLY)
DRILL ONE OR TWO HOLES AS
REQUIRED — HERE OR ON OPPOSITE END.
ONE CORNER OF THE PLASTIC KNOCKOUT IS LIFTED AND BENT
OVER. CHOOSE THE CORNER WHICH IS MOST CONVENIENT.