LTE-I Installation and Setup Guide
6
Compatibility
For a list of control panels that are compatible with various features of this device, go to:
https://mywebtech.honeywell.com/
For UL installations and ULC Commercial Burglary Installations, any compatible UL or ULC (respectively)
Listed Control Panel may be used. Note, that any control panel that does not communicate via Honeywell's
ECP data bus is compatible using zone Trigger Mode. For ULC Commercial Fire Installations, only ULC
Listed Subscriber's Unit Panels which use Honeywell's ECP data bus are compatible.
For UL and ULC Fire and Burglary installations, compatible receivers are:
MX8000
(UL, ULC – can be an be used for secondary reporting in ECP mode,
required in Zone Trigger Mode and for P3 Channel Security in ULC-S304
Installations or ULC-S559 Passive Channel Installations)
7810PC
(UL – PC based software receiver can be used as a primary alarm
receiver. Refer to the Installation and User Guide for requirements.)
7810iR-ENT
(UL, ULC – can be the primary alarm receiver.)
8810iR
(UL, ULC – can be the primary alarm receiver.)
Ademco 685
(UL, ULC – Ademco 685 has not been evaluated by UL.)
UL
The Automation System must be UL1981 listed.
The LTE-I has been evaluated for connection to police station receivers.
ULC
The LTE-I has only been evaluated for communication with listed Model 7810iR-ENT internet
receiver and Model MX8000 central station receiver.
Compliance
This device complies with the following ULC Installation Codes and Standards:
1. The Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, CSA
C22.1.
2. National Building Code (NBC).
3. Standard for Installation and Services for Fire Signal Receiving Centers and Systems,
CAN/ULC-S561-03.
4. Standard for Installation of Fire Alarm Systems, CAN/ULC-S524-06.
5. Standard for Installation and Classification of Burglar Alarm Systems for Financial and
Commercial Premises, Safes and Vaults, CAN/ULC-S302-M91.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell IntelliPath Series and is the answer not in the manual?

Honeywell IntelliPath Series Specifications

General IconGeneral
BrandHoneywell
ModelIntelliPath Series
CategoryCell Phone
LanguageEnglish

Related product manuals