35
.
SECTION 4
Registration
Registering the Communicator
Once you have programmed the communicator, it must be registered to enable the AlarmNet
account. Registering the communicator activates the account with AlarmNet and enables the
security system's control panel to send reports. You can register by using one of the following
methods:
AlarmNet 360 website 7720P Programming Tool
Test Message / Registration switch Phone
LED DESCRIPTION
STATUS
(green)
ON – Is NOT registered with AlarmNet.
OFF – Is registered with AlarmNet.
MESSAGE
(yellow)
ON – Message transmission pending.
QUICK PERIODIC BLINK - Normal
SLOW BLINK – In unison with green LED,
Registration in progress.
FAULT
(red)
OFF – No fault present.
You can monitor the registration process by viewing the display LEDs. The TX/RX (yellow) LED
and the REG (green) LED will blink slowly in unison while registration is in progress.
When the registration successfully completes, the communicator enters a normal operating
mode; the REG (green) LED goes out and the TX/RX (yellow) LED is lit to indicate that the
power-on / reset message is waiting to be sent. This message will appear at the receiving
station as “E339 803”. The description may read “Trouble – Exp. Mod. Reset”. If registration is
not validated within 90 seconds, the communicator times out, and the REG (green) LED will be
lit solid.
Registering through the AlarmNet 360 Website
To register the communicator via the website, go to: www.alarmnet360.com
Log in and follow the on-screen prompts.
Please have the following information available:
Primary City ID (two-digit number).
Primary Central Station ID (two-digit hexadecimal number).
Primary Subscriber ID (four-digit number).
MAC ID and MAC CRC number (located on the box and inside the communicator).
After the communicator is registered, you may log out of the AlarmNet 360 website.
STATUS
MESSAGE
FAULT