LTE-I Installation and Setup Guide
44
Battery Charger
OK
Battery Charger
Indicates the battery charger circuit status (either OK or NOT
OK).
Press the [Space] key to go to the next field.
Press the backspace [BS] key to go to the previous field.
Line Voltage
xx.xxV
Line Voltage Display
The line voltage [this value is the peak voltage from the power
transformer or RMS x 1.414] of the communicator can be
viewed on the 7720P. An asterisk (*) next to the voltage
indicates that this is below the accepted level.
Press the [Space] key to go back to the System Status Display.
Press the backspace [BS] key to go to the previous field.
[T]
Test Msg Sent
Test Alarm
Sends a Test alarm to AlarmNet. Functional for a registered
communicator only. If the device is not registered, a message is
displayed indicating that the command cannot be executed.
[X]
Reset CPU Y/N
Reset the Communicator.
Pressing [N] returns to diagnostic mode (blank screen = enter
next command or escape).
Pressing [Y] resets the communicator (blank screen = reset
complete).
[]
(UP
arrow)
Registering …
Registration
Registers a programmed communicator with AlarmNet.
[]
(DN
arrow)
Enter PIN#
Registration with PIN for Replacement Communicator
Registers a replacement communicator with AlarmNet, once pro-
grammed, using the existing PIN #.
[0]
Force Server Update?
Y/N
Force Upload of Configuration File to Server
Pressing [Y] will force the device to upload its entire configura-
tion file to the server.
Pressing [N] cancels the operation.
NOTE: If the internet is not available, and the communicator is
not initialized when you enter this command, the following
screen will be displayed:
Cannot Upload
Try Later! _
Wait for the RSSI LEDs to light, indicating the communicator has
completed its initialization, and try again.
[ENT
ER]
Strt Prog Mode?
Y/N_
Enter Program Mode
Press [Y] to enter program mode; otherwise, press [N].