11 MeshGuard Sensor Specifications
Sensor
Normal
Range
Resolution
Response
Time
Temperature
Range
H2S
0 to100 ppm
0.1 ppm
T
90
< 30 sec
T
10
< 30 sec
-20° C to +50° C
(-4° F to 122° F)
H2S
0 to1000 ppm
1 ppm
T
90
< 45 sec
T
10
< 45 sec
-40° C to +50° C
(-40° F to 122° F)
LEL/
LEL IR*
0 to 100% LEL
1% LEL
T
90
< 30 sec
T
10
< 30 sec
-40° C to +50° C
(-40° F to 122° F)
CO
0 to 2000 ppm
1 ppm (0 to 2000 ppm)
T
90
< 30 sec
T
10
< 30 sec
-40° C to +50° C
(-40° F to 122° F)
CO2 IR
0 to 5% vol
0 to 100% vol
0.01% vol
0.1% vol
T
90
< 30 sec
T
10
< 30 sec
-40° C to +50° C
(-40° F to 122° F)
O2
0 to 25%
0.10%
T
90
< 15 sec
T
10
< 15 sec
-20° C to +50° C
(-4° F to 122° F)
NH3
0 to 100 ppm
1 ppm
T
90
< 30 sec
T
10
< 90 sec
-20° C to +50° C
(-4° F to 122° F)
CL2
0 to 10 ppm
0.1 ppm
T
90
< 30 sec
T
10
< 30 sec
-20° C to +50° C
(-4° F to 122° F)
SO2
0 to 20 ppm
0 to 100 ppm
0.1 ppm
1 ppm
T
90
< 60 sec
T
10
< 60 sec
-20° C to +50° C
(-4° F to 122° F)
HCN
0 to 50 ppm
0.5 ppm
T
90
< 200 sec
T
10
< 200 sec
-20° C to +50° C
(-4° F to 122° F)
NO
0 to 250 ppm
0.5 ppm
T
90
< 45 sec
T
10
< 45 sec
-20° C to +50° C
(-4° F to 122° F)
PH3
0 to 20 ppm
0.1 ppm
T
90
< 60 sec
T
10
< 60 sec
-20° C to +50° C
(-4° F to 122° F)
HCL
0 to 15 ppm
1 ppm
T
90
< 200 sec
T
10
< 200 sec
-20° C to +50° C
(-4° F to 122° F)
ETO-A
0 to100 ppm
1 ppm
T
90
< 45 sec
T
10
< 10 sec
-20° C to +50° C
(-4° F to 122° F)
ETO-B
0 to10 ppm
0.1 ppm
T
90
< 45 sec
T
10
< 10 sec
-20° C to +50° C
(-4° F to 122° F)
ETO-C
0 to 500 ppm
10 ppm
T
90
< 45 sec
T
10
< 10 sec
-20° C to +50° C
(-4° F to 122° F)
NO2
0 to 20 ppm
0.1 ppm
T
90
< 45 sec
T
10
< 10 sec
-20° C to +50° C
(-4° F to 122° F)
HF
0 to 10 ppm
0.1 ppm
T
90
< 200 sec
T
10
< 200 sec
-20° C to +50° C
(-4° F to 122° F)
* FTD-3000 only.
Ordering Replacement Parts: If you need replacement parts, a list is available online: http://www.raesystems.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell MeshGuard FTD-2000 and is the answer not in the manual?

Honeywell MeshGuard FTD-2000 Specifications

General IconGeneral
BrandHoneywell
ModelMeshGuard FTD-2000
CategoryMonitor
LanguageEnglish

Related product manuals