9–3
Codabar Formatting
³ 1 0 7 7 1 7
Transmit Codabar Start/Stop Characters
Transmits Codabar’s Start/stop characters before
and after each bar code.
³ 1 0 7 7 0 7
* Do Not Transmit Codabar Start/Stop
³ 1 1 5 1 0 0
* Normal Codabar Start/Stop Characters
³ 1 1 5 1 1 0
Enable Transmit Codabar Start/Stop
Characters as Lower Case Characters
³ 1 0 7 7 1 6
Enable CLSI Editing Works only with 14 digit
Codabar type lengths. This option will perform
CLSI type editing before the information is
transmitted to the host.
³ 1 0 7 7 0 6
* Do Not Enable CLSI Editing
³ 1 0 0 4 1 0
Enable Codabar Mod-16 Check Digit
³ 1 0 0 4 0 0
* Disable Codabar Mod-16 Check Digit
³ 1 0 0 4 1 1
Enable Codabar “7-Check” Check Digit
³ 1 0 0 4 0 1
* Disable Codabar “7-Check” Check Digit
³ 1 0 8 0 0 6
* Transmit Codabar Check Digit
³ 1 0 8 0 1 6
Don’t Transmit Codabar Check Digit