104 Xenon XP User Guide
Preferred Symbology Time-out
Once you have enabled Preferred Symbology and entered the high and low priority 
symbologies, you must set the time-out period. This is the period of time the 
scanner will search for a high priority barcode after a low priority barcode has been 
encountered. Scan the barcode below, then set the delay (from 1-3,000 
milliseconds) by scanning digits from the Programming Chart, beginning on page 
311, then Save. Default = 500 ms.
Preferred Symbology Default
Scan the barcode below to set all Preferred Symbology entries to their default 
values.
Output Sequence Overview
Output Sequence Editor
This programming selection allows you to program the scanner to output data 
(when scanning more than one symbol) in whatever order your application 
requires, regardless of the order in which the barcodes are scanned. You can define 
up to 15 barcodes in an output sequence.
Note: To make Output Sequence Editor selections, you’ll need to know the code I.D., code 
length, and character match(es) your application requires. Use the alphanumeric 
symbols from the Programming Chart, beginning on page 311. You must hold the 
trigger while reading each barcode in the sequence.
To Add an Output Sequence
An output sequence is created using a string of serial commands that is sent to the 
scanner. This string is most easily sent to the scanner using the EZConfig software 
tool (see EZConfig for Scanning Introduction on page 237). You can also 
accomplish this by scanning alphanumeric barcodes (see the Programming Chart, 
beginning on page 311).
Preferred Symbology Time-out