EasyManua.ls Logo

Honeywell Xenon XP 1950g - Scanner Charge Pack Status; Base;Access Point Communication and Scanning

Honeywell Xenon XP 1950g
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Xenon XP User Guide 49
Scanner Charge Pack Status
The following charge status feedback is provided by the scanner when the scanner
is out of the base and has been idle for 5 seconds.
When the scanner is out of the base, you can manually initiate a charge level query
by pressing the scanner trigger 3-times in rapid succession (approx. 2 seconds).
The scanner provides the following feedback when a query is initiated.
The following charge status feedback is provided by the scanner while the scanner
resides in the base.
Base/Access Point Communication and Scanning
The following feedback is provided by the base (red LED) or Access Point (blue
LED) and indicates communication and scanning status.
Scanner LED Scanner Beep Charge Level
Yellow, 3 sets of flashes
repeated every 3 seconds
No beep less than 15%
Red, 3 sets of flashes
repeated every 3 seconds
No beep less than 5%
Red, 20 sets of rapid flashes No beep less than 2%
Scanner LED Scanner Beep Charge Level
Red, 3 sets of quick flashes in a row No beep less than 15%
Yellow, 3 sets of quick flashes in a row No beep less than 5%
Green, 3 sets of quick flashes in a row No beep less than 2%
Scanner LED Scanner Beep Charge Level
Red, 2 sets of flashes every 10 seconds No beep less than 20%
Yellow, 2 sets of flashes every 10 seconds No beep 20% ~ 40%
Green, 2 sets of flashes every 10 seconds No beep greater than 40%
Green, steady on No beep 100%
LED Communication Condition
Off USB suspend
On continuously Power on, system idle
Short blinks in multiple pulses. Occurs while
transferring data to/from the RF module or
the Host port.
Receiving data

Table of Contents