Loading...
Xenon XP User Guide 219
U - Update Tries
This sets the maximum number of frames the scanner should take to reach the D -
Delta for Acceptance. Update Tries is only available when using Photo Style (1P).
(Default = 6)
nURange: 0 - 10
% - Target Set Point Percentage
Sets the target point for the light and dark values in the captured image. A setting
of 75% means 75% of the pixels are at or below the target white value, and 25% of
the pixels are above the target white value. Altering this setting from the default is
not recommended under normal circumstances. To alter grayscale values, W -
Target White Value should be used. (Default = 50)
n% Range: 1 - 99
Example:
Step 2 - Ship a Picture Using IMGSHP
Image Ship - IMGSHP
An image is taken whenever the trigger is pressed or when the Image Snap
(IMGSNP) command is processed. The last image is always stored in memory. You
can “ship” the image by using the IMGSHP command.
The image ship commands have many different modifiers that can be used to
change the look of the image output. Modifiers affect the image that is
transmitted, but do not affect the image in memory. Any number of modifiers may
be appended to the IMGSHP command.
Example: You can use the following command to snap and ship a bitmap image with gamma
correction and document image filtering: IMGSNP;IMGSHP8F75K26U.
Target Set Point
Percentage at 97%:
Target Set Point
Percentage at 40%:
Target Set Point
Percentage at 50%: