62 Xenon XP User Guide
Xenon XP 1952g-BF/1952h-BF
Scan one of the barcodes below to set the scanner’s power output to Full Power 
(100%), Medium High Power (87%), Medium Power (50%), or Low Power (1%). 
Default = Full Power.
Batch Mode
Batch mode is used to store barcode data when a scanner is out of range of its base 
or Access Point, or when performing inventory. The data is transmitted to the base 
or Access Point once the scanner is back in range or when the records are manually 
transmitted. 
Note: Batch Mode is only supported by the Honeywell Charge and Communication Base 
(CCB) and Honeywell Access Point (AP). Batch mode has limitations when using 
multiple scanners to one base or Access Point. If a cordless system is being used in 
“multiple link mode,” where up to 3 scanners are to be connected to one base or 
Access Point, some accumulated or batched scans could be lost if scanners are 
constantly being moved in and out of range.
Automatic Batch Mode stores barcode data when the scanner is out of range of 
the base or Access Point. The data is automatically transmitted to the base or 
Access Point once the scanner is back in range. When the scanner’s buffer space is 
full, any barcodes scanned generate an error tone. In order to scan barcodes again, 
the scanner must be moved back into range of the base or Access Point so data can 
be transmitted. 
Inventory Batch Mode stores barcode data, whether or not you are in range of the 
base or Access Point. To transmit the stored data to the base or Access Point, either 
place the scanner in the base, or scan Transmit Inventory Records (page 67). When