50 Xenon XP User Guide
Base Power Communication Indicator
To display the power indicator on a base or an Access Point, scan the Base Power
Communication Indicator On barcode. To turn off the power indicator, scan the
Off barcode. Default = On.
Base Charge Status
When charging the base indicates the progress while the scanner resides in the
base.
Note: The number of scans was measured with a clearly printed UPC code in good light. The
approximate number of scans varies with changes in label quality, Symbology, and
environmental factors.
Low Power Alerts
Note: Low Power Alerts are only supported by battery-free scanners Xenon XP 1952g-BF
and Xenon XP 1952h-BF.
Low power alerts allow you to customize battery-free scanner LEDs to flash in
different patterns when the charge level is low. Use the barcodes that follow to
customize the settings for the power range being configured, the number of
flashes per alert, the interval between flashes, the number of alerts, and the
interval between alerts. The beeper can also be set to silent, or to sound with the
flash patterns.
* Base Power Communication
Indicator On
Base Power Communication
Indicator Off
LED Charge Level
Approximate Expected
Scans (see note)
Green On 100% 450
Green Slow Blink 50-99% 200
Green Fast Blink 30-50% 100
Yellow Fast Blink 0-30% Charging, do not scan