CHAPTER
12
Xenon XP User Guide 275
PRODUCT SPECIFICATIONS
Xenon XP 1950g/1950h Corded Scanner Product
Specifications
Parameter Specification
Mechanical
Height 6.3 inches (160mm)
Length 4.1 inches (104mm)
Width 2.8 inches (71mm)
Weight
General Duty
Healthcare
5.3 ounces (150g)
5.5 ounces (155g)
Electrical
Voltage Requirements 4.4 to 5.5 VDC at input connector
Current Draw ScanningStandby
500mA @ 5VDC, 2.5W
Illumination LED:
Peak Wavelength 624nm +
18nm (red LED)
IEC 62471: “Exempt Risk Group”
442nm, 552nm (white LED)
IEC 62471: “Exempt Risk Group”
Aiming:
Peak Wavelength LED 624nm + 18nm (red LED)
520nm + 18nm (green LED)
IEC 62471: “Exempt Risk Group”
Environmental
Temperature Ranges:
Operating 32°F to 122°F (0°C to 50°C)
Storage -40°F to 158°F (-40°C to 70°C)
Humidity 0 to 95% non-condensing

Table of Contents

Other manuals for Honeywell Xenon XP 1950g

Related product manuals