Xenon XP User Guide 281
Depth of Field Charts
1950g/1952g/1952g-BF Typical Performance
Temperature Ranges:
Operating/Battery Charge 41° F to +104° F (5° C to +40° C)
Storage without battery -40° F to +158° F (-40° C to +70° C)
Humidity Up to 95% non-condensing
Mechanical Drop Operational after 50 drops from 3.3 feet
(1m) to concrete
Vibration 5G Peak from 22Hz to 300Hz
ESD Sensitivity Up to 15kV direct air
Up to 8 kV indirect coupling plane
Sealant Rating IP42
Parameter (Continued) Specification
Focus Standard Range High Density Ultra High Density
Symbology
Near
Distance
Far
Distance
Near
Distance
Far
Distance
Near
Distance
Far
Distance
2 mil Code 39 mm n/a n/a n/a n/a 20 60
in. n/a n/a n/a n/a 0.8 2.4
3 mil Code 39 mm 56 132 27 131 5 90
in. 2.2 5.2 1.1 5.2 0.2 3.5
5 mil Code 39 mm 28 242 14 219 5 115
in. 1.1 9.5 0.6 8.6 0.2 4.5
10 mil Code 39 mm 0 443 0 389 0 205
in. 0 17.4 0 15.3 0 8.1
13 mil UPC mm 0 490 0 368 0 190
in. 0 19.3 0 14.5 0 7.5
7.5 mil Code 128 mm 25 295 5 260 0 120
in. 1.0 11.6 0.2 10.2 0 4.7
15 mil Code 128 mm 0 543 0 417 0 200
in. 0 21.4 0 16.4 0 7.9
20 mil Code 39 mm 4 822 6 604 5 340
in. 0.2 32.4 0.2 23.8 0.2 13.4
5 mil PDF417 mm 54 160 30 155 5 85
in. 2.1 6.3 1.2 6.1 0.2 3.3
6.7 mil PDF417 mm 34 220 17 211 0 100
in. 1.4 8.7 0.7 8.3 0 3.9