58
Alarm
No.
Alarm text Alarm after
(sec.)
Con-
rmation
required
Alarm
repeat
(sec.)
Remedy
19 - 20
48 - 49
Fan speed (1 -2)
exceeded/fallen short of
5 15 Return the fan speed to the limit
range or match the fan alarm speed
accordingly.
21 - 22 Fan speed (1 2)
exceeded/fallen short of
1 15 Check the shaft monitoring for
Maistro or rotary cross harrow.
Check the shaft drive.
23 Seed ow monitoring
system failed
10 60 Check the cable connection to the
seed ow module.
Check the seed ow module.
24 Seed ow in tram line xx 8 8 No grains should fall out when the
tram line gate is closed. Check the
function and leak tightness of the
gate.
Check whether the sensor number
has been entered into the FSG
menu.
25 No seed ow sensor xx 8 8 Check the seed hose no. xx for
blockage.
Check the function of the sensor.
26 - 29 Filling level (hopper 1 - 4)
fallen short of
5 yes The hopper (1 - 4) runs empty. The
alarm will only become active again
after the hopper has been lled.
30 - 32
55 -56
Motor (1 - 4) speed too
high
5 yes 5 The alarm will be displayed above
135 rpm. Filling the cells is no
longer assured for all types of seed.
Reduce the working speed.
install a bigger rotor.
43 - 44 Double placement in row
No placement in row
8 8 When sowing single grains (Maistro):
Check working speed, metering unit,
setting and seed.
50 - 53 Metering unit (1 - 4)
empty
5 yes 10 Monitoring of bridging in hopper.
Metering unit (1 - 4) empty. Stop
immediately, no seed or fertiliser
is sown.
Sporadic failure of work
signal.
<2 The alarm appears in case of short
interruption (< 2 seconds) of the
work signal. Check oating position
of hydraulics, switch for work signal
and speed signal.