30 INSTALLATION MANUAL
VISUAL COOKING II SMART EDITION
POWER CONNECTION
Power Power kW Electric consumption A
1.06 1.10 1.16 1.20 2.06 2.10 2.20 1.06 1.10 1.16 1.20 2.06 2.10 2.20
400V 3N ~ 50-60Hz 9 18 24 36 21 27 60 13 26 35 52 31 39 87
415V 3N ~ 50-60Hz 9 18 24 36 21 27 60 13 25 34 50 30 38 84
400V 3 ~ 50-60Hz 9 18 24 36 21 27 60 13 26 35 52 31 39 87
440V 3 ~ 50-60Hz 9 18 24 36 21 27 60 12 24 32 47 28 36 79
480V 3 ~ 50-60Hz 9 18 24 36 21 27 60 11 22 29 44 26 33 73
200V 3 ~ 50-60Hz 9 18 24 36 21 27 60 26 52 70 104 61 78 174
208V 3 ~ 50-60Hz 9 18 24 36 21 27 60 25 50 67 100 59 75 167
230V 3 ~ 50-60Hz 9 18 24 36 21 27 60 23 45 60 91 53 68 151
Power Fuse protection = A Cable size mm
2
*
1.06 1.10 1.16 1.20 2.06 2.10 2.20 1.06 1.10 1.16 1.20 2.06 2.10 2.20
400V 3N ~ 50-60Hz 16 35 50 63 35 50 100 5x2,5 5x4 5x10 5x10 4x6 5x10 5x25
415V 3N ~ 50-60Hz 16 35 50 63 35 50 100 5x2,5 5x4 5x10 5x10 4x6 5x10 5x25
400V 3 ~ 50-60Hz 16 35 50 63 35 50 100 4x2,5 4x4 4x10 4x10 4x6 4x10 4x25
440V 3 ~ 50-60Hz 16 35 50 63 35 35 100 4x2,5 4x4 4x10 4x10 4x4 4x6 4x25
480V 3 ~ 50-60Hz 16 25 35 50 35 35 80 4x2,5 4x4 4x6 4x10 4x4 4x6 4x25
200V 3 ~ 50-60Hz 35 63 100 125 80 100 200 4x4 4x16 4x25 4x35 4x16 4x25 4x70
208V 3 ~ 50-60Hz 25 63 80 125 63 100 200 4x4 4x10 4x25 4x35 4x16 4x25 4x70
230V 3 ~ 50-60Hz 25 50 80 100 63 80 200 4x4 4x10 4x25 4x35 4x16 4x25 4x70
Power Fuse protection = A Cable size mm
2
1.06 1.10 1.16 1.20 2.06 2.10 2.20 1.06 1.10 1.16 1.20 2.06 2.10 2.20
115V 1N ~ 50-60Hz 10 10 20 N/A 10 20 3x2,5 3x2,5 3x2,5 N/A 3x2,5 3x2,5
230V 1N ~ 50-60Hz 10 10 20 N/A 10 20 3x2,5 3x2,5 3x2,5 3x2,5 3x2,5 3x2,5
Power Power kW Electricity consumption A
1.06 1.10 1.16 1.20 2.06 2.10 2.20 1.06 1.10 1.16 1.20 2.06 2.10 2.20
115V 1N ~ 50-60Hz 1 1 2 N/A 1 2 8,5 8,5 17 N/A 8,5 17
230V 1N ~ 50-60Hz 1 1 2 N/A 1 2 8,5 8,5 17 N/A 8,5 17
VISUAL COOKING II SMART EDITION GAS UNITS:
POWER CONNECTION