HP 54 Basic Cutter - Perform Length Calibration; Change the user

HP 54 Basic Cutter
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3.
Press . System setup appears on the screen.
4.
Press .
5.
Press or to scroll through the menu until you reach Calibrations. Press .
6.
Press or to scroll through the menu until you reach Cal. length. Press .
7.
Press again. The cutter reloads the substrate and starts the length calibration. Take out the substrate
and measure the length of the cut line. The length to be entered is the distance between line 1 and line 2,
as shown below.
NOTE: The cutter can only be as accurate as the accuracy of the calibration itself. If your measuring device
is inaccurate, then re-calibrating may reduce the cutter’s accuracy. For maximum accuracy, you are
recommended to set the cutter to Metric units of measurement for the calibration.
8.
Use , , , and to change the value on the screen to the length that you measured
between the two lines along the length of the vinyl roll.
9.
Press to conrm.
10.
Use , , , and to change the value on the screen to the length that you measured
between the two lines across the width of the vinyl roll.
11.
Press to conrm.
12.
Press twice to leave the menu.
Change the user
There are four user congurations, all of which have the same parameters. The parameters can be set to
dierent values for each user, so that you can recongure the cutter for a dierent type of job or substrate
quickly and easily by selecting a dierent user.
NOTE: Initially, the parameters are set to the same values for all users.
These are the most important cutting parameters that can be saved for dierent users:
Speed | Pressure | Oset | Tool
FlexCut settings
Substrate and length calibration values
Overcut
Paneling
ENWW Change the user 21