EasyManua.ls Logo

HP DL360 - ProLiant - G3 - Page 108

HP DL360 - ProLiant - G3
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Server Specifications
F-2 HP ProLiant DL360 Generation 3 Server Setup and Installation Guide
HP CONFIDENTIAL
Writer: Richard O. Heath File Name: k-appf Server Specifications.doc
Codename: Ertl Part Number: 293974-001 Last Saved On: 10/11/02 11:24 AM
Table F-1: Operating and Performance Specifications continued
Specifications
Power supply output
Rated steady-state power 325 W
Maximum peak power 325 W
Temperature range
Operating (See note) 10°C to 35°C 50°F to 95°F
Shipping (See note) -40°C to 70°C -40°F to 158°F
Relative humidity (noncondensing)
Operating (See note) 10% to 90%
Non-operating (See note) 5% to 95%
Maximum wet bulb temperature 28°C 82.4°F
NOTE: Operating temperature has an altitude derating of 1°C per 304.8 M
(1,000 ft). No direct sunlight. Storage maximum humidity of 95% is based on a
maximum temperature of 45°C. Altitude minimum for storage is 70 KPa.