Installing Hardware Options 
HP ProLiant DL360 Generation 3 Server Setup and Installation Guide  2-19 
 
HP CONFIDENTIAL 
Writer: Richard O. Heath File Name: c-ch2 Installing Hardware Options.doc 
Codename: Ertl Part Number: 293974-001 Last Saved On: 10/16/02 1:34 PM 
7.  Install the Processor Power Module into socket 2 (1) and close the locking 
latches (2). 
 
Figure 2-15:  Installing a Processor Power Module 
 
NOTE:  PPMs with the same part number may look different, but are functionally equivalent. 
Installing a Hot-Plug Redundant Power Supply 
 
NOTE:  Only one PCI slot is supported when the server utilizes two hot-plug redundant power 
supplies. 
Use this section to install a hot-plug redundant power supply. 
Hot-Plug Power Supply Setup 
The server can be configured with a single hot-plug AC or DC power supply or two 
hot-plug AC or two hot-plug DC power supplies. When two hot-plug power supplies 
are installed, the server has power redundancy. Depending on the server 
configuration, procedures for installing or replacing the power supplies vary per the 
following: