Installing Hardware Options
2-26 HP ProLiant DL360 Generation 3 Server Setup and Installation Guide
HP CONFIDENTIAL
Writer: Richard O. Heath File Name: c-ch2 Installing Hardware Options.doc
Codename: Ertl Part Number: 293974-001 Last Saved On: 10/16/02 1:34 PM
3. Connect the battery module cable to the battery-backed write cache enabler
battery pack (1) and to the Smart Array 5i memory connector on the system
board (2).
4. Route the battery module cable through the battery-backed write cache cable clip
on the system board (3).
NOTE: If necessary, remove the PCI riser board assembly to access the cable clip. Refer
to “Removing an Expansion Board” in this chapter, for more information.
Figure 2-22: Routing and connecting the battery-backed
write cache enabler cable (PCI riser board 1 removed for
clarity)
5. Reinstall the PCI riser board assembly into slot 1.
6. Reverse the procedures in the “Accessing Internal Server Components” section
earlier in this chapter.