Table 5-2 Computer Setup—Security (continued)
Option Description
F1 to boot
Allow user to reject
No prompts
BIOS SureStart
Verify Boot Block on every boot – Select to enable HP SureStart.
BIOS Data Recovery Policy – Select Automatic or Manual to determine data recovery process. Manual
recovery is intended only for situations when you want forensic analysis before HP SureStart
recovery. When this policy is set to manual, HP SureStart will not correct any issues that are found
until the local user enters the manual recovery key sequence. This can result in a computer that
cannot boot until the manual recovery key sequence is input.
Dynamic Runtime Scanning of Boot Block. Veries the integrity of the BIOS boot block region several
times each hour while the computer is running. Default is Enabled.
Sure Start BIOS Settings Protection. When enabled, HP Sure Start locks all critical BIOS settings and
provides enhanced protection for these settings using nonvolatile (ash) memory.
NOTE: An administrator password must be set to activate this setting.
Enhanced HP Firmware Runtime Intrusion Prevention and Detection – Enables monitoring of HP
system rmware executing out of main memory while the operating system is running. Any
anomalies detected in HP system rmware that is active while the operating system is running will
result in a Sure Start security event being generated.
Sure Start Security Event Policy—controls HP Sure Start behavior upon identifying a critical security
event (any modication to HP rmware) while the operating system is running.
Log Event Only—HP Sure Start will log all critical security events in the HP Sure Start audio log
within the HP Sure Start nonvolatile (ash) memory.
Log Event and notify user—In addition to logging all critical security events, HP Sure Start will
notify the user within the operating system that a critical event has occurred.
Log Event and power o system—In addition to logging all critical security events, HP Sure
Start turns of the computer upon detecting a HP Sure Start Security Event. Because of the
potential for data loss, HP recommends this setting only in situations where security integrity
of the system is a higher priority than the risk of potential data loss.
Secure Platform Management (SPM)
HP Sure Run Current State
SPM Current State
Physical Presence Interference
When selected, the user is notied at system power up when changes have been made to system security
policy, and the user must manually agree to those changes before they are conrmed.
Smart Cover
Cover Removal Sensor
Lets you disable the cover sensor or congure what action is taken if the computer cover was removed.
Default is Disabled.
NOTE:
Notify user alerts the user with a POST error on the rst boot after the sensor detects removal of
the cover. If the password is set, Administrator Password requires that the password be entered to boot
the computer if the sensor detects that the cover has been removed.
Intel Software Guard Extensions (SGX)
Computer Setup (F10) Utilities 71

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP EliteOne G5 and is the answer not in the manual?

HP EliteOne G5 Specifications

General IconGeneral
ChipsetIntel Q370
MemoryUp to 64GB DDR4
StorageUp to 2TB HDD or 1TB SSD
GraphicsIntel UHD Graphics 630
Display23.8"
AudioBang & Olufsen
NetworkingBluetooth 5.0
PortsUSB 3.1
Operating SystemWindows 10 Pro
CPUIntel Core i5/i7 (9th Gen)

Related product manuals