• A diagnostic LED only illuminates for physical processor core errors, when isolation is to a
specific IPF processor module. If there is any uncertainty about a specific processor, then the
customer is pointed to the SEL for any action, and the suspect IPF processor module CRU LED
on the System Insight Display does not illuminate.
• For configuration-type errors (for example, when no IPF processor module is installed in
processor slot 0) all of the CRU LEDs on the diagnostic LED panel illuminate for all of the IPF
processors that are missing.
• No diagnostic messages are reported for single-bit errors that are corrected in both instruction
and data caches, during CMC events to any physical processor core. Diagnostic messages
are reported for CMC events when thresholds are exceeded for single-bit errors; fatal processor
errors cause global / local MCA events.
Table 29 Processor events that illuminate SID LEDs
NotesSourceCauseSample IPMI EventsDiagnostic
LEDs
This event
follows other
SFWProcessor
failed and
deconfigured
Type E0h, 39d:04d
BOOT_DECONFIG_CPU
Processors
failed
processors
Threshold
exceeded for
WIN AgentToo many
cache errors
Type E0h, 5823d:26d
PFM_CACHE_ERR_PROC
Processors
cache paritydetected by
processor errors on
processor
Threshold
exceeded for
WIN AgentToo many
corrected
Type E0h, 5824d:26d
PFM_CORR_ERROR_MEM
Processors
cache errorserrors detected
by platform from
processor
corrected by
ICH10
Power Pod
voltage is out
iLO MPVoltage on
CRU is
inadequate
Type 02h, 02h:07h:03h
VOLTAGE_DEGRADES_TO_NON_RECOVERABLE
Processors
of range
(likely too
low)
Table 30 Processor events that might illuminate SID LEDs
NotesSourceCauseSample IPMI EventsDiagnostic
LEDs
SFWInstalled
processors are
not compatible
Type E0h, 734d:26d
BOOT_CPU_LOADING_ERROR
Processors
SFWProcessors
and/or
Type E0h, 2953d:26d
BOOT_CPU_LOADING_ERROR
Processors
termination out
of order
SFWA logical
processor
Type E0h, 36d:26d
BOOT_CPU_LATE_TEST_FAIL
Processors
(thread) failed
late self test
SFWA logical
processor
Type E0h, 677d:26d
MC_RENDEZVOUS_SLAVES_FAIL
Processors
(thread) slave
HP Confidential80 Troubleshooting

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP integrity rx2900 i4 and is the answer not in the manual?

HP integrity rx2900 i4 Specifications

General IconGeneral
BrandHP
Modelintegrity rx2900 i4
CategoryServer
LanguageEnglish

Related product manuals