Chapter 5
69
5 Troubleshooting
Troubleshooting Tips
WARNING Before removing a cover to service components that cannot be hot-swapped, always
disconnect the AC power cords and unplug telephone cables. Disconnect telephone
cables to avoid exposure to shock hazard from telephone ringing voltages.
Disconnect the AC power cords to avoid exposure to high energy levels that may
cause burns when parts are short-circuited by metal objects such as tools or jewelry.
CAUTION Do not operate the HP Server for more than 10 minutes with any cover (including power
supplies and disk drives) removed. Otherwise, damage to system components may result due to
improper cooling airflow.
However, you can safely remove a cover while the HP Server is running to remove and replace
PCI hot-plug boards. For any other service activity requiring access to the system board or
power distribution board, power-down the HP Server and observe all safety precautions.
Troubleshooting Methodology
Step 1. This is the entry point to the troubleshooting process. Here, you pick from a set of symptoms,
ranging from very simple (System LED is blinking) to the most difficult Machine Check Abort
(MCA) has occured. The following is a list of symptom examples:
System LED blinking
System Alert present on console
System will not power-up
System will not boot
Event/Error Message received
Machine Check Abort (MCA)
Step 2. This step narrows down the observed problem to the specific troubleshooting procedure required.
Here you isolate the failure to a specific part of the server so that you can perform more detailed
troubleshooting. For example:
Problem-System LED blinking
System Alert on console?
Analyze the alert by using the system event log (SEL) to identify the last error logged by
the baseboard management controller. Use either the EFI shell command line interface
(CLI) or the optional management processor card is installed, use the MP commands to
view the SEL.

Table of Contents

Other manuals for HP Integrity rx4640

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity rx4640 and is the answer not in the manual?

HP Integrity rx4640 Specifications

General IconGeneral
BrandHP
ModelIntegrity rx4640
CategoryServer
LanguageEnglish

Related product manuals