EasyManua.ls Logo

HP MSR1003-8S

HP MSR1003-8S
471 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
150
undo poe pd-description
Default
No description is available for the PD that connects to a PI.
Views
PI view
Predefined user roles
network-admin
Parameters
text: Configures a description for the PD connected to the PI, a case-sensitive string of 1 to 80 characters.
Examples
# Configure the description for the PD as IP Phone for Room 101.
<Sysname> system-view
[Sysname] interface gigabitEthernet 2/0/1
[Sysname-GigabitEthernet2/0/1] poe pd-description IP Phone For Room 101
poe pd-policy priority
Use poe pd-policy priority to enable PI power management.
Use undo poe pd-policy priority to restore the default.
Syntax
poe pd-policy priority
undo poe pd-policy priority
Default
PI power management is disabled.
Views
System view
Predefined user roles
network-admin
Usage guidelines
If PI power management is enabled, when a PSE is overloaded, the PSE allocates power to new PDs
based on the priority of their PIs. Otherwise, the PSE does not supply power to new PDs.
Examples
# Enable PI power management.
<Sysname> system-view
[Sysname] poe pd-policy priority
Related commands
poe priority

Table of Contents

Other manuals for HP MSR1003-8S

Related product manuals