Web and MAC Authentication
Configuring MAC Authentication on the Switch
Syntax: aaa port-access mac-based [e] < port-list > [quiet-period <1 - 65535>]
Specifies the time period, in seconds, the switch should
wait before attempting an authentication request for
a MAC address that failed authentication.
(Default: 60 seconds)
Syntax: aaa port-access mac-based [e] < port-list > [reauth-period <0 - 9999999>]
Specifies the time period, in seconds, the switch
enforces on a client to re-authenticate. When set to 0,
reauthentication is disabled. (Default: 300 seconds)
Syntax: aaa port-access mac-based [e] < port-list > [reauthenticate]
Forces a reauthentication of all attached clients on the
port.
Syntax: aaa port-access mac-based [e] < port-list > [server-timeout <1 - 300>]
Specifies the period, in seconds, the switch waits for a
server response to an authentication request. Depend-
ing on the current max-requests value, the switch sends
a new attempt or ends the authentication session.
(Default: 30seconds)
Syntax: aaa port-access mac-based [e] < port-list > [unauth-vid <vid>]
no aaa port-access mac-based [e] < port-list > [unauth-vid]
Specifies the VLAN to use for a client that fails authen-
tication. If unauth-vid is 0, no VLAN changes occur.
Use the no form of the command to set the unauth-vid to 0.
(Default: 0)
4-25

Table of Contents

Other manuals for HP ProCurve 5406zl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 5406zl and is the answer not in the manual?

HP ProCurve 5406zl Specifications

General IconGeneral
Product NameHP ProCurve 5406zl
CategorySwitch
LayerLayer 3
Operating Temperature32°F to 131°F (0°C to 55°C)
Operating Humidity15% to 95% non-condensing
ManagementSNMP, CLI
Power SupplyRedundant power supplies (optional)
Memory128 MB flash, 512 MB SDRAM