Traffic/Security Filters
Filter Types and Operation
A named source-port filter must first be defined and configured before it can
be applied. In the following example two named source-port filters are
defined, web-only and accounting.
ProCurve(config)# filter source-port named-filter web-
only
ProCurve(config)# filter source-port named-filter
accounting
By default, these two named source-port filters forward traffic to all ports and
port trunks.
To configure a named source-port filter to prevent inbound traffic from being
forwarded to specific destination switch ports or port trunks, the drop option
is used. For example, on a 26-port switch, to configure the named source-port
filter web-only to drop any traffic except that for destination ports 1 and 2, the
following command would be used:
ProCurve(config)# filter source-port named-filter web-
only drop 3-26
A named source-port filter can be defined and configured in a single command
by adding the drop option, followed by the required destination-port-list.
Viewing a Named Source-Port Filter
You can list all source-port filters configured in the switch, both named and
unnamed, and their action using the show command below.
Syntax: show filter source-port
Displays a listing of configured source-port filters, where
each filter entry includes a Filter Name, Port List, and
Action:
Filter Name: The filter-name used when a named
source-port filter is defined. Non-named source-port
filters are automatically assigned the port or port trunk
number of the source port.
Port List: Lists the port and port trunk destinations
using the filter. Named source-port filters that are not in
use display NOT USED.
Action: Lists the ports and port trunks dropped by the
filter. If a named source-port filter has been defined but
not configured, this field is blank.
[ index ]
For the supplied index (IDX) displays the action taken
(Drop or Forward) for each destination port on the switch.
9-8

Table of Contents

Other manuals for HP ProCurve 5406zl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 5406zl and is the answer not in the manual?

HP ProCurve 5406zl Specifications

General IconGeneral
Product NameHP ProCurve 5406zl
CategorySwitch
LayerLayer 3
Operating Temperature32°F to 131°F (0°C to 55°C)
Operating Humidity15% to 95% non-condensing
ManagementSNMP, CLI
Power SupplyRedundant power supplies (optional)
Memory128 MB flash, 512 MB SDRAM