Configuring Port-Based and Client-Based Access Control (802.1X)
Configuring Switch Ports as 802.1X Authenticators
eap-radius Use EAP-RADIUS authentication. (Refer to the
documentation for your RADIUS server application.)
chap-radius Use CHAP-RADIUS (MD-5) authentication.
(Refer to the documentation for your RADIUS server appli-
cation.)
For example, to enable the switch to perform 802.1X authentication using one
or more EAP-capable RADIUS servers:
802.1X (Port-Access)
configured for EAP-
RADIUS authentication.
Configuration command
for EAP-RADIUS
authentication.
Figure 10-4. Example of 802.1X (Port-Access) Authentication
4. Enter the RADIUS Host IP Address(es)
If you select either eap-radius or chap-radius for the authentication method,
configure the switch to use 1, 2, or 3 RADIUS servers for authentication. The
following syntax shows the basic commands. For coverage of all commands
related to RADIUS server configuration, refer to
chapter 6, “RADIUS Authen-
tication and Accounting”.
Syntax: radius host < ip-address >
Adds a server to the RADIUS configuration.
[key < server-specific key-string >]
Optional. Specifies an encryption key for use during
authentication (or accounting) sessions with the spec-
ified server. This key must match the key used on the
RADIUS server. Use this option only if the specified
server requires a different key than configured for the
global encryption key.
10-22

Table of Contents

Other manuals for HP ProCurve 5406zl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 5406zl and is the answer not in the manual?

HP ProCurve 5406zl Specifications

General IconGeneral
Product NameHP ProCurve 5406zl
CategorySwitch
LayerLayer 3
Operating Temperature32°F to 131°F (0°C to 55°C)
Operating Humidity15% to 95% non-condensing
ManagementSNMP, CLI
Power SupplyRedundant power supplies (optional)
Memory128 MB flash, 512 MB SDRAM

Related product manuals