Configuring Port-Based and Client-Based Access Control (802.1X)
General Operating Rules and Notes
If a port on switch “A” is configured as an 802.1X supplicant and is
connected to a port on another switch, “B”, that is not 802.1X-aware,
access to switch “B” will occur without 802.1X security protection.
On a port configured for 802.1X with RADIUS authentication, if the
RADIUS server specifies a VLAN for the supplicant and the port is a trunk
member, the port will be blocked. If the port is later removed from the
trunk, the port will allow authentication of the supplicant. Similarly, if the
supplicant is authenticated and later the port becomes a trunk member,
the port will be blocked. If the port is then removed from the trunk, it will
allow the supplicant to re-authenticate.
If a client already has access to a switch port when you configure the port
for 802.1X authenticator operation, the port will block the client from
further network access until it can be authenticated.
Meshing is not supported on ports configured for 802.1X port-access
security.
A port can be configured as an authenticator or an 802.1X supplicant, or
both. Some configuration instances block traffic flow or allow traffic to
flow without authentication. Refer to
“Configuring Switch Ports To Oper-
ate As Supplicants for 802.1X Connections to Other Switches” on page 10-
42.
To help maintain security, 802.1X and LACP cannot both be enabled on
the same port. If you try to configure 802.1X on a port already configured
for LACP (or the reverse) you will see a message similar to the following:
Error configuring port X: LACP and 802.1X cannot be run together.
10-13

Table of Contents

Other manuals for HP ProCurve 5406zl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 5406zl and is the answer not in the manual?

HP ProCurve 5406zl Specifications

General IconGeneral
Product NameHP ProCurve 5406zl
CategorySwitch
LayerLayer 3
Operating Temperature32°F to 131°F (0°C to 55°C)
Operating Humidity15% to 95% non-condensing
ManagementSNMP, CLI
Power SupplyRedundant power supplies (optional)
Memory128 MB flash, 512 MB SDRAM