80 HP ProLiant DL360 Generation 4 Server Maintenance and Service Guide
Environmental Specifications
Temperature range* Specification
Operating
10°C to 35°C (50°F to 95°F)
Shipping
-40°C to 70°C (-40°F to 158°F)
Maximum wet bulb temperature
28°C (82.4°F)
Relative humidity
(noncondensing)**
Specification
Operating 10% to 90%
Non-operating 5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m
(1.8°F per 1,000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C
(113°F). Altitude maximum for storage corresponds to a pressure minimum of 70 KPa.
Hot-Plug Power Supply Calculations
For hot-plug power supply specifications and calculators to determine electrical
and heat loading for the server, refer to the HP Enterprise Configurator website
(http://h30099.www3.hp.com/configurator/
).
DDR SDRAM DIMM Specifications
NOTE: Use only 256-, 512-MB, 1-GB, or 2-GB; 72-bit wide; 2.5-V;
PC2700 Registered ECC DDR SDRAM. Use HP DDR SDRAM only.
Item Description
Size 256 MB, 512 MB, 1 GB, 2 GB
Width 72 bits
Upgrade requirement Any combination of like-paired DDR SDRAM DIMMs that
provide a minimum of 512 MB