Slot numberSlot number Slot typeSlot type Slot powerSlot power Supported form factorsSupported form factors
1 PCIe5 x16 (16, 8, 4, 1) 75 W Full-height, full-length
2 PCIe4 x8 (4, 1) 25 W Full-height, full-length
3 PCIe4 x8 (4, 1) 25 W Full-height, half-
length
4 PCIe4 x8 (4, 1) 25 W Full-height, half-
length
Drive bay numberingDrive bay numbering
CAUTION:CAUTION:
When a server is purchased without any drive installed, some drive bays might be empty while other drive bays might be
populated with drive blanks. To maintain proper system cooling, do not operate the server without a drive or a drive blank
installed.
4 LFF non-hot-plug drive numbering4 LFF non-hot-plug drive numbering
SATA drives are supported.
Onboard connection for Intel VROC SATA RAID support is through the SlimSAS x4 port 2.