MSL6000 series pass-through mechanism reference guide 27
Figure 17 Mounting a 5U or 10U extension
c. Attach the large tie bar (beveled edge to the inside corner of the PTM base unit and
extension) using four mounting screws (see Figure 18).
Figure 18 Installing tie bars
10.Repeat step 9 for each extension.
11.Remove the bottom stop standoff from the PTM base unit and then attach it to the corresponding
mounting hole (see Figure 18) in the last unit of the extended PTM.
12.Secure the belt tensioner ramp and idler pulley to the extension using the two previously
removed screws (see Figure 16 on page 26).
13.Secure the belt tensioner ramp and idler pulley springs using the two previously removed screws
(see Figure 16 on page 26).