5. Touch Cartridge Cycle. The Cartridge Cycle diagnostic screen is displayed.
Figure 30 Cartridge Cycle diagnostic screen
6. Touch Start to begin testing. The message "Test is running" will display.
7. Touch Stop to end the diagnostic.
Converting a Multi-Unit Library Configuration to Standalone
Configuration
If you are converting a multi-unit library configuration to a standalone configuration, it is beneficial
to do so in the following order:
1. Convert the slave unit(s) to standalone.
2. Convert the master unit to standalone.
3. Power off all libraries.
CAUTION: All libraries must be powered off before disconnecting the motor cable. Failure to do so
will damage the library and PTM.
4. Remove the PTM motor cable.
Verifying the Firmware Level
The recommended minimum firmware level required for a multi-unit library configuration is 3.19 for
DLT only libraries, or 4.04 for LTO Ultrium-compatible libraries.
To verify the firmware level of the master:
1. Apply power to the library:
a. Connect each supplied power cord to each power supply receptacle.