Status Description
Flashing green (2 Hz) Power supply is in Smart redundant state or offline
mode.
Solid amber 12 V fault caused a shutdown; power supply failed
(overvoltage/undervoltage, overtemperature,
overcurrent, short-circuit), fan failed, or input
overvoltage protection
Off No power present or standby power failed
(overvoltage/undervoltage, overtemperature,
overcurrent, short-circuit, fan lock)
Fan module numbering
Supported drives
When one drive cage is installed, the following drive configurations are supported:
• 2 NVMe + 6 SATA
• 2 NVMe + 6 SAS
• 8 SAS/SATA when one of the following controllers is installed
◦ P408i-p
◦ P408i-a
◦ P816i-a
• Embedded SATA: 6 SATA drives
When two drive cages are installed, the following drive configurations are supported:
• 4 NVMe (2/2) + 12 SATA (6/4)
• 4 NVMe (2/2) + 12 SAS (6/6)
• 16 SATA (p816i-a)
16 Fan module numbering