EasyManua.ls Logo

HPE ProLiant DX380 Gen10 - Cabling and Diagrams; Storage Cabling Guidelines; Drive Cabling Diagrams

HPE ProLiant DX380 Gen10
203 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cabling
HPE ProLiant Gen10 DX Servers Storage Cabling Guidelines
When installing cables, observe the following:
All ports are labeled:
System board ports
Controller ports
12G SAS Expander ports
Most data cables have labels near each connector with destination port information.
Some data cables are pre-bent. Do not unbend or manipulate the cables.
Before connecting a cable to a port, lay the cable in place to verify the length of the cable.
When routing cables from the front to the rear of the server, use the cable channels on either side of the chassis.
Cabling diagrams
Use the following tables to find cabling information and diagrams.
Table 3: SAS/SATA kits
Option kit
Cable part number* From To Power cable part
number
Front 2SFF SAS/SATA drive cage (SFF) 869826-001
1
Drive backplane
System board
SAS Expander
Controller
869810-001
6
869825-001
6
Front 2SFF SAS/SATA 1U drive cage
(LFF)
869826-001
1
Drive backplane
System board
SAS Expander
Controller
869810-001
6
Front 8SFF SAS/SATA drive cages 776402-001
4
Drive backplane
System board
SAS Expander
Controller
869825-001
6
Table Continued
Cabling 156

Table of Contents

Related product manuals