CAUTION:
The mixing of different GPU accelerator models is not supported.
8. If AMD FirePro S9150 GPUs are already installed in the server, and additional AMD FirePro S9150
GPUs are now being installed, remove the GPU blank:
a. Loosen the captive screw.
b. Using both hands, gently pull the tab and the rear of the GPU blank.
c. Slide out the GPU blank from the server.
9. If AMD FirePro S9150 GPUs are not installed in the server, remove all GPUs:
a. Loosen the captive screw.
b. Using both hands, gently pull the tab and the rear support bracket to slide out the GPU to access the
power cable.
c. Disconnect the power cable from the GPU, and then remove the GPU from the server.
10. If the existing GPU power cables do not support the AMD FirePro S9150 GPUs, remove the cables from
the server:
a. Remove the screws to release the retention springs. Retain the screws for later use.
b. Release the long GPU power cables from the clip.
Hardware options installation 95