Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
a. Extend the server from the rack.
b. Remove the server from the rack.
4. Remove the access panel.
5. If the Smart Storage battery is not installed, do one of the following:
Remove the air baffle.
If installed on LFF models, remove the midplane drive cage.
6. Locate any NVDIMMs already installed in the server.
7. Verify that all LEDs on any installed NVDIMMs are off.
8. Install the NVDIMM.
1
2
2
9. If it is not already installed, install the Smart Storage battery.
10. Install the access panel.
11. Slide or install the server into the rack.
12. Connect each power cord to the server.
13. Power up the server.
14. If required, sanitize the NVDIMM-Ns. For more information, see NVDIMM sanitization on page 144.
Hardware Components of HPE StoreEasy 1X60 Storage system 143