Loading...
Item Connector
identification
Supported
card types
Fabri
c
Supported ICM bays
1 Mezzanine
connector 1 (M1)
Type C and
Type D
1 ICM 1 and 4
2 Mezzanine
connector 2 (M2)
1
Type C and
Type D
2 ICM 2 and 5
3 Mezzanine
connector 3 (M3)
Type C only 3 ICM 3 and 6
4 Mezzanine
connector 4 (M4)
Type C and
Type D
1 ICM 1 and 4
5 Mezzanine
connector 5 (M5)
2
Type C and
Type D
2 ICM 2 and 5
6 Mezzanine
connector 6 (M6)
Type C 3 ICM 3 and 6
1
When installing a mezzanine option on mezzanine connector 2, processor 3 must be installed.
2
When installing a mezzanine option on mezzanine connector 5, processor 4 must be installed.
DIMM slot locations
DIMM slots are numbered sequentially (1 through 12) for each processor. The supported AMP modes use the
alpha assignments for population order, and the slot numbers designate the DIMM slot ID for spare
replacement.
The colored slots indicate the slot order within each channel:
White — First slot of a channel
Black — Second slot of a channel
The arrow points to the front of the compute module.
80 Component identification