EasyManua.ls Logo

hpmont HD3L Series - Analogue Curve Parameters; Speed Parameters

hpmont HD3L Series
109 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Shenzhen Hpmont Technology Co., Ltd. Appendix A Parameter
HD3L Series Controller User Manual 89
Ref. Code
Function
Setting Range Default
Unit
Attribute Setting
F04.01 Line 1 min. setting 0.0 - F04.03% 0.0% 0.1%
F04.02
Corresponding value of line 1
min. setting
0.0 - 100.0% 0.0% 0.1%
F04.03 Line 1 max. setting F04.01 - 100.0% 100.0% 0.1%
F04.04
Corresponding value of line 1
max. setting
0.0 - 100.0% 100.0% 0.1%
F04.05 Line 2 min. setting 0.0 - F04.07% 0.0% 0.1%
F04.06
Corresponding value of line 2
min. setting
0.0 - 100.0% 0.0% 0.1%
F04.07 Line 2 max. setting F04.05 - 100.0% 100.0% 0.1%
F04.08
Corresponding value of line 2
max. setting
0.0 - 100.0% 100.0% 0.1%
F05: Speed Parameters, on pages 51 - 53
F05.00 Multi-speed 0 0.000 - F00.02m/s 0.000m/s 0.001m/s
F05.01 Multi-speed 1 0.000 - F00.02m/s 0.000m/s 0.001m/s
F05.02 Multi-speed 2 0.000 - F00.02m/s 0.000m/s 0.001m/s
F05.03 Multi-speed 3 0.000 - F00.02m/s 0.000m/s 0.001m/s
F05.04 Multi-speed 4 0.000 - F00.02m/s 0.000m/s 0.001m/s
F05.05 Multi-speed 5 0.000 - F00.02m/s 0.000m/s 0.001m/s
F05.06 Multi-speed 6 0.000 - F00.02m/s 0.000m/s 0.001m/s
F05.07 Multi-speed 7 0.000 - F00.02m/s 0.000m/s 0.001m/s
F05.08 Inspection run speed 0.000 - 0.630m/s 0.200m/s 0.001m/s
F05.09 Battery driven run speed 0.000 - F00.02m/s 0.100m/s 0.001m/s
F05.10
Up forced speed switch
detection value
0.0 - 100.0% (F00.02) 97.0% 0.1%
F05.11
Down forced speed switch
detection value
0.0 - 100.0% (F00.02) 97.0% 0.1%
F05.12 FDT1 0.0 - 100.0% (F00.02) 90.0% 0.1%
F05.13 FDT2 0.0 - 100.0% (F00.02) 90.0% 0.1%
F05.14 FDT1 delay level 0.0 - 100.0% (F00.02) 1.0% 0.1%
F05.15 FDT2 delay level 0.0 - 100.0% (F00.02) 1.0% 0.1%
F05.16 Speed within FAR range 0.0 - 20.0% (F00.02) 1.0% 0.1%
F05.17 Over-speed setting 80.0 - 120.0% (F00.02) 115.0% 0.1%
×
F05.18 Over-speed detection time
0.0 - 2.0s
0.0: Not detect motor over speed
fault
0.2s 0.1s
×
F05.19
Detection value of speed
deviation
0.0 - 30.0% (F00.02) 20.0% 0.1%
×
F05.20
Detection time of speed
deviation
0.0 - 2.0s
0.0: Not detect the excessive speed
deviation fault of motor
1.0s 0.1s
×
F05.21 Unused
F05.22 Creeping speed 0.000 - 0.400m/s 0.050m/s 0.001m/s
A

Table of Contents

Related product manuals