Shenzhen Hpmont Technology Co., Ltd. Chapter 4 Electrical Installation
HD3L Series Controller User Manual 17
4.3 Main Circuit
The bare portions of the power cables must be bound with insulation tapes.
Ensure that AC supply voltage is the same as rated input voltage of HD3L.
4.3.1 Supply and Motor Terminal
Figure 4–1 Size F2
Figure 4–2 Size F3 - F6
Table 4-4 HD3L supply and motor terminal description
Terminal Description
L1, L2, L3 Three-phase AC power input terminals
U, V, W Output terminals, connect to three-phase AC motor
P1, (+) DC reactor connection terminals
(+), (-) DC supply input terminals; DC input terminals of power regenerative unit
(+), BR Braking resistor connection terminals
PE Ground terminal, connect to the ground
Danger
W
arning
POWER
BR
(+) (-)
MOTOR
PE
L3
L1 L2
W
UV
POWER
BR
(+) (-)
MOTOR
PE
L3
L1 L2
W
UV
P1
4