Shenzhen Hpmont Technology Co., Ltd. Chapter 3 Mechanical Installation
HD3L Series Controller User Manual 11
Chapter 3 Mechanical Installation
3.1 Precautions
Do not install if HD3L is incomplete or impaired.
When conveying HD3L, please employ suitable tools according to its weight. Avoid scratch to the product. Be
careful: rollover and drop may cause hurt.
Make sure that HD3L is far from explosive and flammable things.
Do not do wiring operation until power supply is cut off for more than 10 minutes, the internal charge indicator of
HD3L is off and the voltage between (+) and (-) of the main circuit terminals is below 36V.
It is required not only carry the keypad and the cover but also bottom enclosure of HD3L.
Do not let wires, screws or residues fall into HD3L when installing.
3.2 Installation Site Requirement
Ensure the installation site meets the following requirements:
Do not install at direct sunlight, moisture, water droplet location;
Do not install at flammable, explosive, corrosive gas and liquid location;
Do not install at oily dust, fiber and metal powder location;
Be vertical installed on fire-retardant material with a strong support;
Make sure adequate cooling space for HD3L so as to keep ambient temperature between
-10 - + 40;
Install at where the vibration is less than 5.9m/s
2
(0.6g);
Install at where the humidity is less than 95%RH and non-condensing location;
HD3L meets IP20 and Pollution level 2 (Dry, none conducting dust pollution).
Note:
1. It needs derating use if running temperature exceeds 40
. The derating value of the output current of
HD3L shall be 2% for each degree centigrade. Max. allowed temperature is 50
.
2. Keep ambient temperature between -10 - +40
. It can improve the running performance if install at
location with good ventilation or cooling devices.
Danger
W
arning
3