Shenzhen Hpmont Technology Co., Ltd. Appendix A Parameter
HD3L Series Controller User Manual 85
Appendix A Parameter
Attributes are changed:
X”: It denotes that the setting of this parameter cannot be modified when the inverter is in run
status.
O”: It denotes that the setting of this parameter can be modified when the inverter is in run status.
*”: It denotes that the value of this parameter is the actual value which cannot be modified.
Ref. Code
Function
Setting Range Default
Unit
Attribute Setting
d00: Status Display Parameters, on pages 42 - 43
d00.00 Controller series HD3L Actual *
d00.01 Software version of DSP 0.00 - 9.99 Actual *
d00.02
Special software version of
DSP
0.00 - 9.99 Actual *
d00.03 Software version of keypad 0.00 - 9.99 Actual *
d00.04 Elevator running status
Display in 16-bit binary:
Bit0: Controller enable
Bit1: Inspection run
Bit2: MS run
Bit3: Analogue run
Bit4 - Bit7: Unused
Bit8: Brake feedback input
Bit9: Contactor feedback input
Bit10: Up forced speed switch
input
Bit11: Down forced speed
switch input
Bit12: MS terminal 1
Bit13: MS terminal 2
Bit14: MS terminal 3
Bit15: Battery driven run
Actual *
d00.05 Rated current of HD3L 0.1 - 999.9A Actual *
d00.06 Controller status
Display in 16-bit binary:
Bit0: Controller fault
Bit1: Run / stop
Bit2: UP
Bit3: DN
Bit4&5: Acceleration /
Deceleration / Constant
Bit6: Zero-speed signal
Bit7: Run at zero-speed
Bit8: Auto-tuning
Bit9: Speed within FAR
Bit10: Ready to run
Bit11: Brake output
Bit12: Contactor output
Actual *