EasyManua.ls Logo

hpmont HD3L Series - F02: Start & Stop Parameters

hpmont HD3L Series
109 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 6 Function Introduction Shenzhen Hpmont Technology Co., Ltd.
48 HD3L Series Controller User Manual
6.2.3 F02: Start & Stop Parameters
Ref. Code Function Description Setting Range [Default]
F02.00 Start delay time 0.000 - 4.999 [0.000s]
When HD3L receives the run command, it will wait for the delay time set by F02.00 and then start running.
When controlled by keypad (F00.05 = 0), F02.00 is invalid.
F02.01 Brake open delay time 0.000 - 4.999 [0.000s]
Defines the time from zero-speed running to output brake-open command.
F02.01 enables HD3L to enter running status before the brake open, so as to alleviate the impact at start.
F02.02 Retention time of start zero-speed 0.000 - 4.999 [0.000s]
Defines the retention time from brake-open to output with speed. During the retention time, the motor has
output torque, which makes more comfortable.
F02.03 Start speed 0.000 - 0.400 [0.000m/s]
Defines the initial speed required for starting HD3L.
The start speed, if properly set, can minimize the start jerk.
F02.04 Retention time of start speed 0.000 - 4.999 [0.000s]
Defines the time in which HD3L runs at start speed (F02.03) .
F02.05 Brake close delay time 0.000 - 4.999 [0.000s]
Defines the time interval from zero-speed running to output brake-closed command.
F02.06 Retention time of stop zero-speed 0.000 - 4.999 [0.000s]
Defines the time during which the motor runs at zero-speed and has output torque at stop, which makes
more comfortable.
F02.07 Contactor close delay time 0.000 - 4.999 [0.000s]
Defines the running contactor delay release time after the run command is revoked.
F02.08 Start ramp time 0.000 - 2.000 [0.000s]
Defines the time that elevator takes to accelerate from zero to the rated speed (F00.02).
F02.08 = 0, the elevator starts from start speed directly.
F02.09 Unused
Atzero-speed running
F02.08
F02.00 F02.01
F02.02
F02.04
F02.03
F00.02
F02.05
F02.06
F02.07
Speed
Time
Brake
Controller is in running
Contactor output
Run command
Objective speed
0

Table of Contents