Shenzhen Hpmont Technology Co., Ltd. Chapter 5 Operation Instructions
HD3L Series Controller User Manual 37
When setting fourth-level menu, if the parameter is not flashing, it indicates that this parameter can’t
be modified. The possible reasons are as follows:
The function parameter can’t be modified, such as the actual detected parameters or recorded
parameters etc.
Only when the controller stops can the function parameter be modified.
Only unlock password can the function parameter be edited due to the valid password.
Switching display parameters at stop status
The keypad can display six stop parameters (F15.08 - F15.13) in loop. Take the default parameter as an
example, Figure 5–7 shows the switching process at stop status.
Figure 5–7 Switching display parameters at stop status
Unlock user’s password
F01.00 = non-zero, press key to exit to stop / run display status, or detect no press on the keypad
for 5 minutes, the user’s password will be valid. The indicator of keypad will be lighting.
The operation of unlock users password is as shown in Figure 5–8 which takes 4 as the user’s password.
Figure 5–8 Operation of unlocking users password
Hz
AVRPM%
REVFWD ALM LO/RE LOCK
Hz
AVRPM%
REVFWD ALM LO/RE LOCK
Hz
AVRPM%
REVFWD ALM LO/RE LOCK
Hz
AVRPM%
REVFWD ALM LO/RE LOCK
Hz
AVRPM%
REVFWD ALM LO/RE LOCK
Setting speed
F15.08 = 4
Output terminal status
F15.12
=
27
Input terminal status
F15.11 = 26
DC bus voltage
F15.09 = 14
AI1 input voltage
(after calculating)
F15.10 = 16
Hz
AVRPM%
REVFWD ALM LO/RE LOCK
Hz
AVRPM%
REVFWD ALM LO/RE LOCK
Hz
AVRPM%
REVFWD ALM LO/RE LOCK
Hz
AVRPM%
REVFWD ALM LO/RE LOCK
Hz
AVRPM%
REVFWD ALM LO/RE LOCK
1.5s later
Third-level menu
T
h
ird-level
m
e
n
u
U
n
loc
k
p
assw
o
rd s
u
ccess
Set passwordFourth-level menu
5