EasyManua.ls Logo

hpmont HD3L Series - Page 73

hpmont HD3L Series
109 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 6 Function Introduction Shenzhen Hpmont Technology Co., Ltd.
62 HD3L Series Controller User Manual
Ref. Code Function Description Setting Range [Default]
F13.16 AO1 function 0 - 9 [0]
F13.17 AO2 function 0 - 9 [0]
0: Unused.
1: Running speed (0 - max. output speed).
2: Setting speed (0 - max. output speed).
3: Output current (0 - twice rated current of HD3L).
4: Output voltage (0 - 1.2 times rated voltage of HD3L).
5: Bus voltage (0 - 2.2 times rated voltage of HD3L).
6: AI1 input (0 - 10V).
7: AI2 input (-10 - +10V/0 - 20mA).
8: AI3 input (-10 - +10V/0 - 20mA).
9: AI4 input (-10 - +10V/0 - 20mA).
Note:
1. At up, up limit of No. 1 and No. 2 function is corresponding to 10V, while down limit is corresponding to 5V;
2. At down, up limit of No. 1 and No. 2 function is corresponding to 0V, while down limit is corresponding to 5V;
3. Up limit of No. 3 - 5 functions is corresponding to max. output voltage 10V;
4. When the negative voltage of No. 7 - 9 function inputs, the AO will output its absolute value.
F13.18 AO1 bias -100.0 - 100.0 [0.0%]
F13.19 AO1 gain 0.0 - 200.0 [100.0%]
The proportional relation of output can be adjusted by output gain, as shown in the figure below.
The formula is: AO1 actual output = F13.19 × Value before calculating + F13.18.
F13.20 AO2 bias -100.0 - 100.0 [0.0%]
F13.21 AO2 gain 0.0 - 200.0 [100.0%]
Refer to F13.18 and F13.19.
Value after
calculating (V)
0510
100%
Value before
calculating (V)
F13.19=200%
F13.19=100%
Analo
g
ue output and
g
ain
Value after
calculating (V)
010
100%
50%
Value before
calculating (V)
F13.18=50%
F13.18=0
Analo
g
ue output and bias

Table of Contents